Resolving clashes between net-zero energy and acoustics engineering specifications, to enhance low-carbon building performance, regulatory compliance and future skills. Laws and standards comparison between Italy and UK
Conference Proceeding
Danza, L., Scrosati, C., Belussi, L., Scamoni, F., Currie, J., & Smith, S. (2022)
Resolving clashes between net-zero energy and acoustics engineering specifications, to enhance low-carbon building performance, regulatory compliance and future skills. Laws and standards comparison between Italy and UK. In Proceedings: Internoise 2022
Under the CNR (Italy) and RSE (Scotland) joint scientific cooperation agreement, the project deals with the development and enhancing understanding of the technical clashes an...
Indoor CO2 and Thermal Conditions in Twenty Scottish Primary School Classrooms with Different Ventilation Systems during the COVID-19 Pandemic
Journal Article
Bain-Reguis, N., Smith, A., Hollins-Martin, C., & Currie, J. (2022)
Indoor CO2 and Thermal Conditions in Twenty Scottish Primary School Classrooms with Different Ventilation Systems during the COVID-19 Pandemic. Pollutants, 2(2), 180-204. https://doi.org/10.3390/pollutants2020014
Healthy indoor environments influence the comfort, health and wellbeing of the occupants. Monitoring the indoor temperature, relative humidity and CO2 levels in primary school...
Metabolic heat loss in southern elephant seals (Mirounga leonina) differs with stage of moult and between habitats
Journal Article
Paterson, W. D., Chaise, L. L., McKnight, C., Currie, J. I., Thompson, D., Ancel, A., …McCafferty, D. J. (2022)
Metabolic heat loss in southern elephant seals (Mirounga leonina) differs with stage of moult and between habitats. Journal of Thermal Biology, 104, Article 103183. https://doi.org/10.1016/j.jtherbio.2021.103183
The moult in southern elephant seals (Mirounga leonina) represents an especially energetically demanding period during which seals must maintain high skin temperature to facil...
Challenges for the transition to low-temperature heat in the UK: A Review
Journal Article
Reguis, A., Vand, B., & Currie, J. (2021)
Challenges for the transition to low-temperature heat in the UK: A Review. Energies, 14(21), Article 7181. https://doi.org/10.3390/en14217181
To reach net-zero emissions by 2050, buildings in the UK need to replace natural gas boilers with heat pumps and district heating. These technologies are efficient at reduced ...
Increased metabolic rate of hauled-out harbor seals (Phoca vitulina) during the molt
Journal Article
Paterson, W. D., Moss, S. E., Ryan, M., Currie, J., McCafferty, D. J., & Thompson, D. (2021)
Increased metabolic rate of hauled-out harbor seals (Phoca vitulina) during the molt. Physiological and Biochemical Zoology, 94(3), 152-161. https://doi.org/10.1086/713958
Harbor seals (Phoca vitulina) live in cold temperate or polar seas and molt annually, renewing their fur over a period of approximately four weeks. Epidermal processes at this...
Historic Environment Scotland Technical Paper 34: Energy consumption and behaviour profiles for eight traditionally built dwellings
Report
Stinson, J., Bros Williamson, J., Garnier, C., & Currie, J. (2020)
Historic Environment Scotland Technical Paper 34: Energy consumption and behaviour profiles for eight traditionally built dwellings. Edinburgh: Historic Environment Scotland
Over the last decade, there has been an increased awareness of the need to improve the energy efficiency and sustainability of Scotland’s building stock and to fulfl obligatio...
Post-disturbance haulout behaviour of harbour seals
Journal Article
Paterson, W. D., Russell, D. J., Wu, G., McConnell, B., Currie, J. I., McCafferty, D. J., & Thompson, D. (2019)
Post-disturbance haulout behaviour of harbour seals. Aquatic Conservation: Marine and Freshwater Ecosystems, 29(S1), 144-156. https://doi.org/10.1002/aqc.3092
1. The impact of anthropogenic activity associated with the construction of a proposed tidal turbine on harbour seals (Phoca vitulina) was investigated using controlled distur...
Whole-life design and resource reuse of a solar water heater in the UK
Journal Article
Saint, R. M., Pomponi, F., Garnier, C., & Currie, J. I. (2019)
Whole-life design and resource reuse of a solar water heater in the UK. Proceedings of the ICE - Engineering Sustainability, 172(3), 153-164. https://doi.org/10.1680/jensu.17.00068
Passive solar systems are often designed primarily with efficiency in mind, and research efforts are concentrated towards gaining an increase in performance. However, due to t...
Thermal Performance through Heat Retention in Integrated Collector-Storage Solar Water Heaters: A Review
Journal Article
Saint, R. M., Garnier, C., Pomponi, F., & Currie, J. (2018)
Thermal Performance through Heat Retention in Integrated Collector-Storage Solar Water Heaters: A Review. Energies, 11(6), 1615. https://doi.org/10.3390/en11061615
Solar thermal systems are a long-standing technology that is receiving increased attention, in terms of research and development, due to ambitious climate change targets and t...
Numerical and empirical evaluation of a novel building integrated collector storage solar water heater
Journal Article
Garnier, C., Muneer, T., & Currie, J. (2018)
Numerical and empirical evaluation of a novel building integrated collector storage solar water heater. Renewable Energy, 126, 281-295. https://doi.org/10.1016/j.renene.2018.03.041
Integrated collector storage is a long established simple low cost solar water heater configuration combining the solar collector with a storage tank into a single unit. Previ...