An evaluation of eye tracking technology in the assessment of 12 lead electrocardiography interpretation
Journal Article
Breen, C. J., Bond, R., & Finlay, D. (2014)
An evaluation of eye tracking technology in the assessment of 12 lead electrocardiography interpretation. Journal of Electrocardiology, 47(6), 922-929. https://doi.org/10.1016/j.jelectrocard.2014.08.008
Introduction
This study investigated eye tracking technology for 12 lead electrocardiography interpretation to Healthcare Scientist students.
Methods
Participants (n = 33) in...
Assessing computerized eye tracking technology for gaining insight into expert interpretation of the 12-lead electrocardiogram: an objective quantitative approach
Journal Article
Bond, R., Zhu, T., Finlay, D., Drew, B., Kligfield, P., Guldenring, D., …Clifford, G. (2014)
Assessing computerized eye tracking technology for gaining insight into expert interpretation of the 12-lead electrocardiogram: an objective quantitative approach. Journal of Electrocardiology, 47(6), 895-906. https://doi.org/10.1016/j.jelectrocard.2014.07.011
Introduction
It is well known that accurate interpretation of the 12-lead electrocardiogram (ECG) requires a high degree of skill. There is also a moderate degree of variabili...
Recording a standard 12 - lead electrocardiogram. An approved methodology by the Society of Cardiological Science and Technology (SCST). Clinical guidelines by consensus.
Other
Baxter, S., Blackman, S., Breen, C., Brown, C., Campbell, B., Cox, C., …Ross, C. (2014)
Recording a standard 12 - lead electrocardiogram. An approved methodology by the Society of Cardiological Science and Technology (SCST). Clinical guidelines by consensus
The effects of electrode misplacement on clinicians’ interpretation of the standard 12-lead electrocardiogram
Journal Article
Bond, R., Finlay, D., Nugent, C., Breen, C., Guldenring, D., & Daly, M. (2012)
The effects of electrode misplacement on clinicians’ interpretation of the standard 12-lead electrocardiogram. European Journal of Internal Medicine, 23(7), 610-615. https://doi.org/10.1016/j.ejim.2012.03.011
Introduction
This study investigates how a particular incorrect electrode configuration affects the 12-lead Electrocardiogram (ECG).
Methods
A correct and an incorrect 12-lea...
Evaluation of a direct access cardiac arrhythmia monitoring service
Journal Article
Skipsey, D. A., Dawson, F. M., Breen, C., & Leslie, S. J. (2012)
Evaluation of a direct access cardiac arrhythmia monitoring service. Cardiology, 19(1), 70-75. https://doi.org/10.5603/CJ.2012.0010
Background: This paper describes the clinical outcomes from a novel direct access arrhythmia monitoring service.
Methods: The study was carried out in the north of Scotland....
A smartphone based telemedicine system for recording limited lead body surface potential maps
Conference Proceeding
Finlay, D., Nugent, C., Breen, C., Bond, R., & Moore, G. (2009)
A smartphone based telemedicine system for recording limited lead body surface potential maps. In 2009 36th Annual Computers in Cardiology Conference (CinC) (237-240
In this paper we describe the development of a limited lead BSPM system which is based around a commercial 12-lead ECG acquisition unit and a smartphone. We repositioned the s...