Raman spectroscopy links differentiating osteoblast matrix signatures to pro-angiogenic potential

Journal Article
Sharma, A., Goring, A., Staines, K., Emery, R., Pitsillides, A. A., Oreffo, R. O., …Clarkin, C. E. (2020)
Raman spectroscopy links differentiating osteoblast matrix signatures to pro-angiogenic potential. Matrix Biology Plus, 5, https://doi.org/10.1016/j.mbplus.2019.100018
Mineralization of bone is achieved by the sequential maturation of the immature amorphous calcium phase to mature hydroxyapatite and is central to the process of bone developm...

UV treatment of microorganisms on artificially-contaminated surfaces using excimer and microwave UV lamps

Journal Article
Christofi, N., Misakyan, M. A., Matafonova, G., Barkhudarov, E. M., Batoev, V., Kossyi, I. A., & Sharp, J. (2008)
UV treatment of microorganisms on artificially-contaminated surfaces using excimer and microwave UV lamps. Chemosphere, 73(5), 717-722. https://doi.org/10.1016/j.chemosphere.2008.06.059
An XeBr excilamp having a peak emission at 283 nm, and microwave UV lamps with peak emissions at 253.7 nm that also generate ozone, have been tested for ability to eradicate h...

An analytical derivation of a popular approximation of the Voigt function for quantification of NMR spectra.

Journal Article
Bruce, S. D., Higinbotham, J., Marshall, I. & Beswick, P. H. (1999)
An analytical derivation of a popular approximation of the Voigt function for quantification of NMR spectra. Journal of magnetic resonance. 142, 57-63. doi:10.1006/jmre.1999.1911. ISSN 1090-7807
The approximation of the Voigt line shape by the linear summation of Lorentzian and Gaussian line shapes of equal width is well documented and has proved to be a useful functi...

Choice of spectroscopic line shape model affects metabolite peak areas and area ratios.

Journal Article
Marshall, I., Bruce, S. D., Higinbotham, J., MacLullich, A., Wardlaw, J. M., Ferguson, K. J. & Seckl, J. (1999)
Choice of spectroscopic line shape model affects metabolite peak areas and area ratios. Magnetic Resonance in Medicine. 44, 646-649. doi:10.1002/1522-2594(200010)44:43.0.CO;2-0. ISSN 0740-3194
The use of Lorentzian model lineshapes leads to systematic errors in the quantification of in vivo (1)H NMR spectra. Experimental lineshapes are better modeled by the Voigt (m...

Use of Voigt line shape for quantification of in Vivo ‘H spectra.

Journal Article
Marshall, I., Higinbotham, J., Bruce, S. D., & Freise, A. (1997)
Use of Voigt line shape for quantification of in Vivo ‘H spectra. Magnetic Resonance in Medicine, 37, 651-657. https://doi.org/10.1002/mrm.1910370504
Quantification of NMR visible metabolites by spectral modeling usually assumes a Lorentzian or Gaussian lineshape, despite the fact that experimental lineshapes are neither. T...