Discrepancies between theoretical and actual heating demand in Scottish modern dwellings

Conference Proceeding
Bros Williamson, J., Stinson, J., Garnier, C., & Currie, J. (2017)
Discrepancies between theoretical and actual heating demand in Scottish modern dwellings. In PLEA 2017 Proceedings - Design to Thrive, (361-368
The study reports on the differences between the actual heat consumption profiles of twelve dwellings monitored for four years and their predicted heat demand profiles as calc...

Energy Behaviour Change by Coloured In-Home Display

Conference Proceeding
Stinson, J., Reid, A., Bros-Williamson, J., & Currie, J. (2016)
Energy Behaviour Change by Coloured In-Home Display. In 41st IAHS WORLD CONGRESS: Conference Proceedings
It is estimated that by 2020 some 53 million, next-generation gas and electricity meters, commonly known as ‘smart meters’, will be installed in approximately 30 million homes...

The thermal retrofitting of walls windows and ceilings in traditional Scottish buildings.

Conference Proceeding
Stinson, J., Bros Williamson, J., Reid, A., & Currie, J. (2015)
The thermal retrofitting of walls windows and ceilings in traditional Scottish buildings. In W. F. Florez-Escobar, C. A. Brebbia, F. Chejne, & F. Mondragon (Eds.), Energy and Sustainability VI, (317-326). https://doi.org/10.2495/ESUS150271
This paper documents research undertaken to evaluate the thermal transmittance of building elements – walls, windows and ceilings – both before and after the addition of insul...

Energy performance evaluation of a passive house built to Scottish building standards.

Conference Proceeding
Bros Williamson, J., Stinson, J., & Currie, J. (2014)
Energy performance evaluation of a passive house built to Scottish building standards
Ensuring that predicted (simulated) energy performance figures are realised once a building is in-use has been of growing concern since issues surrounding the ‘performance gap...